Socomec MODULYS GP 25–600kVA modular UPS

Brand:

Unique, fully modular and redundant three-phase UPS from 25 to 600 kVA/kW. Hot-swap plug-in power modules raise the installed power in steps of 25 kW, with no single point of failure and up to 96.5% efficiency in double conversion mode.

Socomec MODULYS GP 25–600kVA modular UPS

Brand:

Unique, fully modular and redundant three-phase UPS from 25 to 600 kVA/kW. Hot-swap plug-in power modules raise the installed power in steps of 25 kW, with no single point of failure and up to 96.5% efficiency in double conversion mode.

About this item

  • Fully modular: plug-in power module, plug-in battery module and plug-in auxiliary mains bypass module, with top or bottom connection and a top-air exhaust module
  • Redundant: N+1 and N+x redundancy, no centralised parallel control and totally independent power modules, with a redundant parallel bus connection in a ring configuration
  • Efficiency: up to 96.5% in online double conversion mode, verified by TÜV SÜD
  • Serviceability: connections, switches, manual bypass, power modules and all electrical parts are front-access, and modules are hot-swappable while the load stays protected in double conversion
  • Automatic firmware alignment: a new power module aligns its firmware by itself, with no human intervention and with the load protected in inverter mode
  • Forever Young concept: module compatibility guaranteed for 20+ years, with a company declaration of 20-year compatibility
  • Battery ready: plug-in battery module that can be hot-swapped without shutting down the load, and ready for Li-Ion batteries
  • Communications: 7-inch multilingual colour touch screen, Modbus, BACnet/IP, NET VISION web/SNMP and the SoLive UPS mobile app

Key details

Model MODULYS GP
Input
Voltage 400 V three-phase + neutral (340 V to 480 V)
Frequency 50/60 Hz ±10%
Power factor / THDI > 0.99 / < 1.5%
Output
Power factor 1 (according to IEC/EN 62040-3)
Voltage 380 / 400 / 415 V ±1%, three-phase + neutral

See all technical details

Technical details

Model MODULYS GP
Input
Voltage 400 V three-phase + neutral (340 V to 480 V)
Frequency 50/60 Hz ±10%
Power factor / THDI > 0.99 / < 1.5%
Output
Power factor 1 (according to IEC/EN 62040-3)
Voltage 380 / 400 / 415 V ±1%, three-phase + neutral
Frequency 50/60 Hz ±0.1%
Voltage distortion < 1% linear load, < 3% non-linear load
Short-circuit current Up to 3 × In
Overload 125% for 10 minutes, 150% for 1 minute
Crest factor 3:1
Bypass
Voltage Rated output voltage ±15% (configurable from 10% to 20%)
Efficiency (TÜV SÜD verified)
Online double conversion mode Up to 96.5%
Environment
Ambient temperature 0 °C to 40 °C (15 to 25 °C for maximum battery life)
Relative humidity 0 to 95% without condensation
Maximum altitude 1000 m without derating (3000 m maximum)
Acoustic level at 1 m < 55 dBA
System cabinet
Depth 890 mm
Height 1975 mm
Degree of protection IP20
Power module
Height 3U
Weight 34 kg
Type Hot plug-in / hot-swappable
MTBF > 1,000,000 hours (calculated and verified)
Standards
Safety IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMC IEC/EN 62040-2 Class C2, AS 62040.2
Performance VFI-SS-111, IEC/EN 62040-3, AS 62040.3
Seismic compliance Uniform Building Code UBC:1997, IEC 60068-2-57:2013
Environmental IEC/EN 62040-4
Product declaration CE, RCM (E2376), EAC, UKCA

Product description

The benefit of a fully modular system

  • Easy to manage: a totally modular system for scaling the power or adapting quickly to business changes, with standardised modules covering a wide range of power and backup times.
  • Pay as you need: no prior expenditure for unpredictable future extensions in power and backup time, and no installation rework when new capacity is needed.
  • Everything front-access: connections, switches, manual bypass, the auxiliary mains static bypass, the power modules and all electrical parts are reached from the front, so no extra clearance is needed at the back and installation and maintenance are quick and safe.

Totally redundant design

The MODULYS GP is designed for no single point of failure. Each power module is independent, there is no centralised parallel control, and the parallel bus is connected in a ring. Redundancy of N+1 or N+x can be chosen to match the load.

Enhanced serviceability

  • Hot-swap parts: power modules, the auxiliary mains bypass and electronic boards.
  • The load stays fully protected in double conversion mode (VFI) during power module replacement.
  • A 3-colour LED bar shows the status of each power module at a glance.
  • The battery can be hot-swapped without shutting down the connected equipment, and maintenance can be concurrent.

Tested and certified

Green Power 2.0 MODULYS GP is certified by TÜV SÜD for product safety (EN 62040-1), and its efficiency and performance are tested and verified by TÜV SÜD. The power module MTBF is calculated at more than 1,000,000 hours by SERMA Technologies (IEC 62380). The UPS has been tested by CESI against Zone 4 seismic events, and it is RoHS compliant.

Hybrid bypass and monitoring

A hybrid bypass architecture places distributed inverter bypasses in parallel with a segregated, centralised auxiliary mains bypass, creating a redundant solution. Remote monitoring is available through the SoLink 24/7 service and the SoLive UPS mobile app, with an IoT gateway for Socomec cloud services and a remote touch-screen panel.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.