APC Symmetra LX 16kVA scalable rack-mount UPS

Brand:

APC Symmetra LX 16kVA rack-mount UPS with scalable N+1 architecture and double-conversion protection. See single-phase rack UPS details.

APC Symmetra LX 16kVA scalable rack-mount UPS

Brand:

APC Symmetra LX 16kVA rack-mount UPS with scalable N+1 architecture and double-conversion protection. See single-phase rack UPS details.

About this item

  • Output: 16 kVA / 12.8 kW, configurable for 120/208 V or 120/240 V, with outlets for battery-backed loads
  • Redundant and scalable: N+1 rack-mount system with redundant, scalable double-conversion online protection
  • Bypass: internal automatic and manual bypass, with an optional external bypass
  • Input: 45–65 Hz auto-sensing, input power factor 0.98 and total harmonic distortion below 7% at full load
  • Batteries: four maintenance-free sealed lead-acid battery modules with suspended electrolyte, a typical recharge time of 3 hours and a life of 3 to 5 years
  • Management: multi-function LCD console, Web/SNMP management card (AP9631), RS-232, RJ-45 10/100 Base-T and a Smart-Slot

Key details

ModelSYA16K16RMP
Output
Output power capacity12.8 kW / 16.0 kVA
Nominal output voltage120 V, 208 V (configurable 120/208 or 120/240 V)
Output voltage distortionLess than 5% at full load
Output frequency, synchronised to mains47–63 Hz
Output frequency, not synchronised60 Hz ±0.1% for 60 Hz nominal, 50 Hz ±0.1% for 50 Hz nominal

See all technical details

Technical details

ModelSYA16K16RMP
Output
Output power capacity12.8 kW / 16.0 kVA
Nominal output voltage120 V, 208 V (configurable 120/208 or 120/240 V)
Output voltage distortionLess than 5% at full load
Output frequency, synchronised to mains47–63 Hz
Output frequency, not synchronised60 Hz ±0.1% for 60 Hz nominal, 50 Hz ±0.1% for 50 Hz nominal
Load crest factorUp to 5:1
TopologyDouble conversion online
WaveformSine wave
Output connections(8) NEMA L5-20R and (4) NEMA L14-30R (battery backup)
BypassInternal (automatic and manual), optional external bypass
Input
Nominal input voltage208 V
Input frequency45–65 Hz (auto-sensing)
Input connectionHard wire, 4-wire (2PH + N + G)
Input voltage range for main operations96–138 V (line to neutral)
Input total harmonic distortionLess than 7% at full load
Other input voltages240 V
Input power factor at full load0.98
Batteries and runtime
Battery typeMaintenance-free sealed lead-acid with suspended electrolyte, leakproof
Included battery modules4
Typical recharge time3 hours
Replacement batterySYBT5
Expected battery life3–5 years
Communications and management
Interface portsDB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot
Pre-installed SmartSlot cardAP9631
Control panelMulti-function LCD status and control console
Audible alarmAudible and visible alarms prioritised by severity
Emergency power off (EPO)Yes
Physical
Height836 mm (32.9 in)
Width472 mm (18.6 in)
Depth688 mm (27.1 in)
Rack height19U
Net weight286.8 kg (631 lb)
Shipping weight340.5 kg (749 lb)
ColourBlack, silver
Environment
Operating temperature0–40 °C
Operating relative humidity0–95%
Operating elevation0–3000 m
Storage temperature−15 to 45 °C
Audible noise at 1 m62.0 dBA
Heat dissipation online4995 BTU/hr
Conformance
ApprovalsCSA, FCC Part 15 Class A, OSHPD, UL 1778
Standard warranty2 years repair or replace
Voltage versionThis datasheet is for the 208/240 V version; confirm the version you need with us

Product description

Redundant, scalable single-phase protection

The APC Symmetra LX 16kVA scalable rack-mount UPS provides redundant single-phase power protection. Explore rack-mount UPS architecture, N+1 redundancy and double-conversion UPS operation.

The Symmetra LX is a highly available single-phase UPS. Its architecture is redundant and scalable, so capacity can match the load and a failed module does not take the load down. This 16 kVA rack-mount version is configured N+1.

Double conversion online

The load is always supplied from the inverter, with a sine-wave output. The UPS has an internal automatic and manual bypass, and an external bypass can be added as an option.

Batteries and runtime

The system uses maintenance-free, sealed lead-acid batteries with a suspended electrolyte, which are leakproof. Four battery modules are included, and the typical recharge time is 3 hours. Runtime can be extended with additional battery options.

Management

A multi-function LCD console gives local status and control, with audible and visible alarms prioritised by severity. The included Web/SNMP management card (AP9631), the RS-232 and RJ-45 10/100 Base-T ports and the Smart-Slot support monitoring and management over the network.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.