APC Smart-UPS VT 20kVA 400V three-phase UPS

Brand:

APC Smart-UPS VT 20kVA three-phase UPS with four battery modules and internal maintenance bypass. See online UPS power protection details.

APC Smart-UPS VT 20kVA 400V three-phase UPS

Brand:

APC Smart-UPS VT 20kVA three-phase UPS with four battery modules and internal maintenance bypass. See online UPS power protection details.

About this item

  • Output: 20 kVA / 16 kW, 400 V three-phase, configurable for 380, 400 or 415 V nominal output voltage
  • Online double conversion: sine-wave output with less than 5% voltage distortion at full load and 95.3% efficiency at full load
  • Bypass: built-in maintenance bypass and static bypass, with parallel capability
  • Batteries: four VRLA battery modules ship installed, with a typical recharge time of 5 hours and an expected battery life of 3 to 5 years
  • Management: multi-function LCD status and control console, RS-232 and Smart-Slot with the AP9631 network management card, and emergency power off (EPO)
  • Quiet and compact: 51.3 dBA at 1 m in a 1490 × 523 × 842 mm cabinet

Key details

ModelSUVTP20KH4B4S
Output
Output power capacity16.0 kW / 20.0 kVA
Nominal output voltage400 V three-phase (configurable 380, 400 or 415 V)
Efficiency at full load95.3%
Output voltage distortionLess than 5% at full load
Output frequency, synchronised to mains47–53 Hz for 50 Hz nominal

See all technical details

Technical details

ModelSUVTP20KH4B4S
Output
Output power capacity16.0 kW / 20.0 kVA
Nominal output voltage400 V three-phase (configurable 380, 400 or 415 V)
Efficiency at full load95.3%
Output voltage distortionLess than 5% at full load
Output frequency, synchronised to mains47–53 Hz for 50 Hz nominal
Output frequency, not synchronised50 Hz ±0.1%
Load crest factor3:1
TopologyDouble conversion online
WaveformSine wave
Maximum output current32 A
BypassBuilt-in maintenance bypass, built-in static bypass
Input
Nominal input voltage400 V three-phase
Input frequency40–70 Hz (auto-sensing)
Input connectionHard wire, 5-wire (3PH + N + G)
Input voltage range for main operations304–477 V
Other input voltages380, 415 V
Maximum input current27.0 A
Input power factor at full load0.98
Batteries and runtime
Battery typeVRLA
Included battery modules4
Typical recharge time5 hours
Nominal battery voltage±192 V (split battery referenced to neutral)
Expected battery life3–5 years
Replacement battery cartridges4
End of discharge battery voltage±154 V
Communications and management
Interface portsDB-9 RS-232, Smart-Slot
Pre-installed SmartSlot cardAP9631 network management card
Control panelMulti-function LCD status and control console
Audible alarmAudible and visible alarms prioritised by severity
Emergency power off (EPO)Yes
Physical
Height1490 mm
Width523 mm
Depth842 mm
Net weight599 kg
Shipping weight630 kg
ColourBlack
Environment
Operating temperature0–40 °C
Operating relative humidity0–95%
Operating elevation0–1000 m
Storage temperature−50 to 40 °C
Audible noise at 1 m51.3 dBA
Heat dissipation online3112 BTU/hr
Protection classIP20
Conformance
Approvals and standardsCE, C-tick, RCM, EN 50091-2, EN/IEC 62040-3, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, ISO 9001, VFI-SS-111
Standard warranty1 year repair or replace, with start-up service

Product description

Three-phase protection with batteries inside

The APC Smart-UPS VT 20kVA 400V three-phase UPS is designed for critical electrical loads. Review online three-phase UPS features, internal battery modules and business power protection.

The Smart-UPS VT is an effective 10–40 kVA three-phase UPS that protects mission-critical applications against downtime and data loss. This 20 kVA unit ships with its battery modules and power modules installed, so it arrives ready to connect.

Online double conversion

The inverter supplies the load continuously, so equipment never runs directly from the mains. The output is a clean sine wave with less than 5% distortion at full load, and the 3:1 crest factor accepts the peaks of electronic loads.

Maintenance and expansion

  • A built-in maintenance bypass lets the UPS be serviced without switching the load off.
  • A built-in static bypass transfers the load automatically if the UPS needs to be taken out of the circuit.
  • Parallel capability allows more capacity or redundancy to be added later.

Management

A multi-function LCD console shows the status and gives local control, and audible and visible alarms are prioritised by severity. The Smart-Slot takes the AP9631 network management card for monitoring over the network, and an RS-232 port and emergency power off are provided.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.