Brand:

12 V 200 Ah VRLA gel battery with front terminals for 19″ and 23″ racks and cabinets; 12-year design float life at 25 °C.

Narada MPG 12V 200Ah battery

Brand:

12 V 200 Ah VRLA gel battery with front terminals for 19″ and 23″ racks and cabinets; 12-year design float life at 25 °C.

About this item

  • 12 V, 200 Ah VRLA battery (10-hour rate, to 1.80 V per cell at 25 °C) with gel electrolyte and flat plates
  • Front terminals (M8 female) for simple, safe installation on a relay rack tray or in a closed cabinet
  • Fits standard 19" and 23" racks and cabinets; top and side-of-monobloc connection options
  • Central gas collection system available to the customer's requirements
  • Design float life of 12 years at 25 °C (77 °F)
  • Self-discharge: residual capacity above 90% after 90 days of storage at 25 °C

Key details

Model MPG12V200
Battery type VRLA (valve-regulated lead-acid), gel electrolyte, flat plates
Nominal voltage 12 V
Rated capacity 200 Ah (10-hour rate, to 1.80 V per cell at 25 °C / 77 °F)
Design float life 12 years at 25 °C (77 °F)
Typical weight 67.0 kg

See all technical details

Technical details

Model MPG12V200
Battery type VRLA (valve-regulated lead-acid), gel electrolyte, flat plates
Nominal voltage 12 V
Rated capacity 200 Ah (10-hour rate, to 1.80 V per cell at 25 °C / 77 °F)
Design float life 12 years at 25 °C (77 °F)
Typical weight 67.0 kg
Internal resistance About 3.0 mΩ
Terminal Front terminal, M8 female
Terminal hardware torque 8 ± 1.0 N·m
Container material ABS (V0 optional)
Operating temperature, maximum range -40 °C to 50 °C (-40 °F to 122 °F)
Operating temperature, recommended 15 °C to 25 °C (59 °F to 77 °F)
Storage temperature -20 °C to 40 °C (-4 °F to 104 °F)
Float (standby) charge voltage 2.25 V per cell at 25 °C (range 2.23 to 2.27 V per cell)
Equalize and cycle service charge voltage 2.35 V to 2.40 V per cell at 25 °C (cycle use: 2.40 V per cell, range 2.35 to 2.45 V per cell)
Recommended maximum charging current limit 50 A (0.25 C)
Self-discharge Residual capacity above 90% after 90 days of storage at 25 °C (77 °F)
Installation Suitable for 19" and 23" racks or closed cabinets; top or side-of-monobloc connection options; central gas collection system available on request

Product description

The MPG range VRLA batteries use flat plates with gel electrolyte and a front terminal design. The design makes installation simple and safe on a standard relay rack tray or in a closed cabinet. The MPG range has a high energy density and suits 19″ and 23″ racks and cabinets, with options for top connection and side-of-monobloc connection. A central gas collection system can be fitted to the customer’s requirements. The design float life is 12 years at 25 °C (77 °F).

Constant current discharge

Discharge current in amperes to the end voltage shown, at 25 °C (77 °F).

End voltage per cell5 min15 min30 min45 min1 h2 h3 h4 h5 h6 h8 h10 h12 h20 h24 h
1.60 V655353214154124.571.455.943.038.632.325.220.717.5710.949.13
1.67 V616340210153123.571.154.942.738.232.224.920.417.3710.849.05
1.70 V610334207152122.570.554.642.537.832.224.920.517.2710.849.04
1.75 V560324205151121.568.754.042.037.331.924.620.317.2710.749.03
1.80 V502301197145117.568.153.641.936.331.324.520.117.0710.649.02
1.83 V479276193140112.467.351.940.035.130.223.919.416.3710.648.87
1.85 V449268178135109.464.850.539.434.329.623.119.216.2610.448.80
Constant current discharge characteristics, amperes at 25 °C (77 °F)

Constant power discharge

Discharge power in watts per cell to the end voltage shown, at 25 °C (77 °F).

End voltage per cell5 min15 min30 min45 min1 h2 h3 h4 h5 h6 h8 h10 h12 h20 h24 h
1.60 V1096619386290233.9134.5106.482.373.962.248.840.134.0421.5918.07
1.67 V1055608383288232.9134.5105.482.273.662.148.339.833.7321.5918.07
1.70 V1048601383288231.9133.5105.481.972.962.248.239.633.4321.4918.07
1.75 V979597381287228.9133.5103.481.872.561.947.739.533.4321.4918.07
1.80 V914563372280227.9132.5103.481.670.861.347.739.333.3321.4918.07
1.83 V881516368272218.9131.5101.478.669.359.647.238.332.6321.3917.87
1.85 V835504342261211.8126.598.477.667.658.445.838.032.4320.9817.77
Discharge data with constant power, watts per cell at 25 °C (77 °F)

Source: manufacturer datasheet MPG12V200-03-N-EN (Ver.03, January 2016). Subject to revision without prior notice. The outline dimensions are in the drawing on the datasheet; download it with the button above.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.