Eaton 93PM 50–200kW scalable UPS

Brand:

Three-phase, transformer-free double-conversion UPS from Eaton in ratings from 30 to 200 kW: up to 97% efficiency, above 99% in Energy Saver System mode, scalable modular architecture and Hot Sync paralleling.

Eaton 93PM 50–200kW scalable UPS

Brand:

Three-phase, transformer-free double-conversion UPS from Eaton in ratings from 30 to 200 kW: up to 97% efficiency, above 99% in Energy Saver System mode, scalable modular architecture and Hot Sync paralleling.

About this item

  • Efficiency: up to 97% in double conversion mode and above 99% in Energy Saver System (ESS) mode
  • Scalable: modular architecture with pay-as-you-grow capacity, in ratings from 30 to 200 kW
  • Availability: Hot Sync wireless paralleling and internal redundancy, with N+1 versions at 50, 100 and 150 kW
  • Input: power factor 0.99, input current distortion below 3% (below 4.5% at 30 kW), voltage range up to +20% and down to −15% at full load
  • Output: 220/380, 230/400 or 240/415 V, 50/60 Hz, three phase plus neutral, with load power factor from 0.8 lagging to 0.8 leading
  • Management: Web and SNMP interfaces as standard, three communication bays, USB, five relay inputs, a dedicated EPO and one relay output

Key details

Model 93PM
General
UPS output power rating (1.0 p.f.) 30, 40, 50, 60 kVA / 54 kW, 80, 100, 120, 150, 160 and 200 kW
Efficiency in double conversion mode Up to 97%
Efficiency in Energy Saver System (ESS) mode More than 99%
Inverter / rectifier topology Transformer-free IGBT with PWM
Audible noise 30–50 kW: below 60 dBA; 80–200 kW: below 65 dBA; ESS operation: below 47 dBA

See all technical details

Technical details

Model 93PM
General
UPS output power rating (1.0 p.f.) 30, 40, 50, 60 kVA / 54 kW, 80, 100, 120, 150, 160 and 200 kW
Efficiency in double conversion mode Up to 97%
Efficiency in Energy Saver System (ESS) mode More than 99%
Inverter / rectifier topology Transformer-free IGBT with PWM
Audible noise 30–50 kW: below 60 dBA; 80–200 kW: below 65 dBA; ESS operation: below 47 dBA
Altitude without derating 1,000 m (maximum 2,000 m)
Field upgradeable Yes
Input
Input wiring 3ph + N + PE / 3ph + PE
Nominal input voltage (configurable) 220/380, 230/400, 240/415 V, 50/60 Hz
Input voltage range High: +20% on the rectifier input. Low: −15% at 100% load, −40% at 50% load, without battery discharge
Input frequency range 40–72 Hz
Input power factor 0.99
Input current distortion (ITHD) 30 kW: below 4.5%; 40–200 kW: below 3%
Soft start Yes
Internal backfeed protection Yes
Output
Output wiring 3ph + N + PE
Nominal output voltage (configurable) 220/380, 230/400, 240/415 V, 50/60 Hz
Output voltage distortion (UTHD) Below 1% (100% linear load), below 5% (reference non-linear load)
Rated output power factor 1.0
Permitted load power factor 0.8 lagging to 0.8 leading
Overload on inverter 10 min at 102–110%, 60 s at 111–125%, 10 s at 126–150%, 300 ms above 150%
Overload when bypass available Continuous below 125%, 10 ms at 1000%
Overload on battery 300 ms above 126%
Batteries
Battery type VRLA
Charging method ABM technology or float
Temperature compensation Optional
Battery nominal voltage (VRLA) From 432 V (36 × 12 V, 216 cells) to 480 V (40 × 12 V, 240 cells)
Maximum charging current (at 40 kW per power module) 30–50 kW: 29.3 A; 80–100 kW: 58.6 A; 120–150 kW: 87.9 A; 160–200 kW: 117.2 A
Battery start capability Yes
Communications
MiniSlot connectivity Web/SNMP, ModBus/Jbus, industrial relay; 3 communication bays
Ports Built-in host and device USB
Relay inputs / outputs 5 relay inputs and a dedicated EPO, 1 relay output (standard)
Compliance
Safety IEC 62040-1 (CB certified)
EMC IEC 62040-2
Performance IEC 62040-3

Product description

Maximum energy efficiency, minimum operating costs

The 93PM sets its operating efficiency at up to 97% in double conversion mode, which cuts running costs, and delivers more than 99% in Energy Saver System (ESS) mode. High power and energy density keep the footprint compact.

Highly scalable and reliable

A scalable, modular architecture with pay-as-you-grow capability keeps the initial investment low. Eaton's Hot Sync wireless paralleling and internal redundancy give high availability and reliability.

Easy deployment

Thermal management support allows installation against a wall, in rows and in hot/cold aisle layouts. Easy access allows fast repair, and a wide range of options and accessories is available: external battery cabinets with long-life batteries, an external maintenance bypass switch, an integrated manual bypass and MiniSlot connectivity.

Easy management

Web and SNMP interfaces are standard. Intelligent Power software integrates with leading virtualisation management systems, and the LCD user interface with visual data logging gives clear information on the status of the UPS.

Key applications

  • Small, medium and large data centres
  • Modular and virtualised data centres
  • Mission-critical applications
  • IT infrastructure

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.