Aros Sentry HPS HT-120kVA three-phase UPS

Brand:

Aros Sentry HPS HT-120kVA three-phase UPS with online double conversion, 120kVA/96kW output and parallel expansion. See industrial UPS details.

Aros Sentry HPS HT-120kVA three-phase UPS

Brand:

Aros Sentry HPS HT-120kVA three-phase UPS with online double conversion, 120kVA/96kW output and parallel expansion. See industrial UPS details.

About this item

  • Output: 120 kVA / 96 kW, 380 / 400 / 415 V three-phase + neutral (selectable), nominal current 174 A
  • Online double conversion (VFI): filtered, stabilised sinusoidal output, immune to interference on the supply line thanks to special input and output filters
  • Efficiency: 93% in online mode and up to 98% in ECO mode, which reduces energy dissipation and cost
  • Overload: 110% for 300 seconds, 125% for 10 minutes and 150% for 1 minute; bypass overload capacity of 1000% for 10 ms
  • Parallel and redundant: can be connected in parallel even after the first unit is installed, with parallel, Dual Bus and Dynamic Dual Bus configurations; digital control balances the currents between units
  • Battery care: periodic battery test, protection against deep discharge and temperature-compensated recharge; a high battery current suits large battery banks
  • Generator friendly: low input harmonic distortion and a high input power factor; a motor generator kit is available on request
  • Safety and communication: back-feed protection fitted as standard, Aros Watch & Save software, RS-232, dry contacts and an EPO contact

Key details

ModelSentry HPS HT120
Input
Nominal voltage400 V three-phase ±20%
Frequency45–65 Hz
Power factor0.92 with input filter
Current harmonic distortion (THDi)5% with input filter
Soft start0–100% in 10 seconds

See all technical details

Technical details

ModelSentry HPS HT120
Input
Nominal voltage400 V three-phase ±20%
Frequency45–65 Hz
Power factor0.92 with input filter
Current harmonic distortion (THDi)5% with input filter
Soft start0–100% in 10 seconds
By-pass line
Nominal voltage400 V three-phase + neutral
Permitted voltage range±15% (selectable from ±10% to ±25% from the front panel)
Nominal frequency50 or 60 Hz
Permitted frequency range±2% (selectable from ±1% to ±5% from the front panel)
Overload capacity for 10 ms1000%
By-passStatic and manual for maintenance
Transfer time0 ms (2–4 ms in ECO mode)
Batteries
Number of battery cells (Pb)240
Nominal battery voltage530 V
TypeSealed lead-acid, vented lead-acid, nickel-cadmium
Maximum recharge current35 A (at about 80% load)
Recharging voltageVariable according to the temperature (−0.5 V × °C)
Ripple voltage< 1%
Output
Nominal power120 kVA
Active power at cos φ 0.896 kW
Nominal voltage380 / 400 / 415 V three-phase + neutral (selectable)
Voltage stability±1% static, ±5% dynamic
Nominal current174 A
Frequency50 / 60 Hz
Frequency stability±0.05% on battery, ±2% in synchronism with the mains (±5% selectable)
Crest factor (EN 62040-3)3:1
Overload110% for 300 s, 125% for 10 min, 150% for 1 min
System
AC-AC efficiency93% online, 98% ECO mode
Operating altitude without derating1000 m a.s.l.
Noise at 1 m60–65 dBA, depending on load and temperature
Operating temperature0–40 °C
Relative humidity95% (non-condensing)
StandardsSafety EN 62040-1, EMC IEC 62040-2 and EN 50091-2, EN 62040-3
Back-feed protectionStandard
Protection degreeIP20
ColourRAL 7035
Battery cabinets (40 minutes backup)
Cabinets2 × A100, each 860 × 740 × 1800 mm
Battery blocks2 × 40
Weight of the battery cabinets2940 kg

Product description

Quality power supply

The Aros Sentry HPS HT-120kVA three-phase UPS uses online double-conversion technology for stable power. Explore 120kVA industrial UPS operation, VFI power protection and parallel expansion.

The Sentry HPS is an online double conversion (VFI) UPS with a filtered and stabilised sinusoidal output voltage. It is immune to interference on the supply line because it has special input and output filters.

Maximum reliability and power availability

Digital control by a microprocessor monitors all the internal parameters and reduces the number of electronic components, which lowers the likelihood of breakdowns. In parallel connections, the digital control balances the currents between the units, which change over time with vibration and temperature, and exchanges information without manual tuning. The Sentry HPS is designed so that it can be connected in parallel even after the first unit has been installed, in parallel, Dual Bus or Dynamic Dual Bus configurations.

High efficiency and maximum battery care

  • ECO mode can raise efficiency up to 98%. The mains is the priority source and the load is switched to the inverter only when the mains characteristics exceed the preset limits.
  • Battery management includes a periodic battery test, protection against deep discharge and temperature-compensated recharge.
  • The high battery current lets large battery banks be recharged in 10 hours, as battery manufacturers recommend.

Motor generator friendly

The input filter options give low harmonic distortion and a high power factor at the input, which makes the UPS well suited to use with a motor generator. On request the HPS series is supplied with a motor generator kit that inhibits battery recharging and/or synchronisation with the bypass.

Safety and communication

A back-feed protection device prevents voltage from feeding back to the upstream distribution board, for the safety of personnel. Aros Watch & Save software shows the input and output voltage, the load applied and the remaining backup time, and can program the automatic shutdown of open systems after a prolonged blackout. Hardware interfaces include an RS-232 serial port, dry contacts and an EPO (emergency power off) contact.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.