APC Symmetra PX 500kW modular UPS with maintenance bypass

Brand:

APC Symmetra PX 500kW modular UPS for data centres, with scalable power modules and maintenance bypass. See critical power protection details.

APC Symmetra PX 500kW modular UPS with maintenance bypass

Brand:

APC Symmetra PX 500kW modular UPS for data centres, with scalable power modules and maintenance bypass. See critical power protection details.

About this item

  • Output: 500 kW / 500 kVA at 400 V three-phase, with 480, 415 and 380 V also supported
  • Efficiency: 96% at full load in double conversion online operation, with a 0.99 input power factor
  • Clean power: output voltage distortion below 2% with linear loads and below 3% with non-linear loads, voltage tolerance ±1% static and ±5% at a 100% load step
  • Overload: 125% for 10 minutes and 150% for 60 seconds
  • Bypass: built-in maintenance bypass and built-in static bypass, with a typical transfer time of 2 ms
  • Batteries: 32 VRLA battery modules included, a typical recharge time of 3.5 hours and a battery design life of 5 to 8 years
  • Control: touch-screen LCD user interface and a network management card 2 with environmental monitoring, out-of-band access and Modbus

Key details

ModelSY500K500DL-PD
Output
Rated power500,000 W / 500,000 VA
Main output voltage400 V three-phase (480 V three-phase also supported)
Other output voltages380 V, 415 V
Output voltage tolerance±1% static, ±5% at a 100% load step
Output voltage distortion< 2% linear load, < 3% non-linear load

See all technical details

Technical details

ModelSY500K500DL-PD
Output
Rated power500,000 W / 500,000 VA
Main output voltage400 V three-phase (480 V three-phase also supported)
Other output voltages380 V, 415 V
Output voltage tolerance±1% static, ±5% at a 100% load step
Output voltage distortion< 2% linear load, < 3% non-linear load
Output frequency, synchronised to mains50 Hz or 60 Hz
Output frequency, not synchronised50 Hz ±0.1% or 60 Hz ±0.1%
TopologyDouble conversion online
WaveformSine wave
Load power factor0.5 leading to 0.5 lagging
Overload125% for 10 minutes, 150% for 60 seconds
Efficiency at full load96%
Input
Main input voltage400 V three-phase (480 V and 415 V also supported)
Input voltage range340–460 V at 400 V, 408–552 V at 480 V
Input frequency40–70 Hz (auto-sensing)
Input connectionHard wire 4-wire (3PH + G) or 5-wire (3PH + N + G)
Input power factor at full load0.99
Input total harmonic distortionLess than 5% at full load
Input protection3-pole breaker
Maximum short-circuit withstand (Icw)50 kA
Bypass
Bypass typeBuilt-in maintenance bypass, built-in static bypass
Bypass voltage tolerance±10%, settable from ±4, 6, 8 and 10%
Transfer time2 ms typical
Batteries and runtime
Battery typeVRLA
Included battery modules32
Typical recharge time3.5 hours
Battery charge power47,262 W rated
Battery design life5–8 years
Replacement battery cartridges6
Communications and management
Control panelTouch-screen LCD user interface
Pre-installed SmartSlot cardNetwork management card 2 with environmental monitoring, out-of-band access and Modbus
Emergency power off (EPO)Optional
Physical
Height1991 mm (78.4 in)
Width5200 mm (204.7 in)
Depth1070 mm (42.1 in)
Net weight8521 kg (18,785.6 lb)
ColourBlack
Power module slots20
Environment
Operating temperature0–40 °C (32–104 °F)
Operating relative humidity0–95%
Storage temperature−15 to 40 °C
Acoustic level54 dBA
Heat dissipation61,893 Btu/h
Degree of protectionIP20 (NEMA 1)
Conformance
StandardsEN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, UL 1778, CSA C22.2 No. 107.3-05, UL 60950-1
CertificationscUL listed, UL listed, Eurobat general purpose
Provided equipmentAssembly service, installation guide, network management card, start-up service, user manual
Contractual warranty12 months

Product description

Modular and scalable

The APC Symmetra PX 500kW modular UPS is a scalable three-phase power protection system for data centres. Review 500kW data centre UPS features, modular UPS capacity and maintenance bypass.

The Symmetra PX is a modular, scalable UPS: power modules are added as the load grows, up to the 500 kW rating of this configuration, without rebuilding the installation. The configuration shown here is supplied with a maintenance bypass and a distribution cabinet.

High efficiency and clean power

Double conversion online operation reaches 96% efficiency at full load with an input power factor of 0.99 and input harmonic distortion below 5%. The output keeps its voltage within ±1% under static load and ±5% at a 100% load step, with total distortion below 2% on linear loads and below 3% on non-linear loads.

Bypass and overload

  • Built-in maintenance bypass for servicing without interrupting the load.
  • Built-in static bypass with a typical transfer time of 2 ms.
  • Overload capacity of 125% for 10 minutes and 150% for 60 seconds.

Batteries

The system includes 32 VRLA battery modules, with a typical recharge time of 3.5 hours and a battery design life of 5 to 8 years. The UPS also supports customer-specific battery solutions with 144 cells for runtime optimisation.

Monitoring

A touch-screen LCD user interface gives local control, and the network management card 2 provides web access, environmental monitoring, out-of-band access and Modbus.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.