APC Smart-UPS RT 10kVA online UPS

Brand:

APC Smart-UPS RT 10kVA online UPS with 8kW output, double conversion and four internal battery modules. See scalable runtime details.

APC Smart-UPS RT 10kVA online UPS

Brand:

APC Smart-UPS RT 10kVA online UPS with 8kW output, double conversion and four internal battery modules. See scalable runtime details.

About this item

  • Rating: 10 kVA / 8 kW, 230 V single-phase output, configurable for 220 or 240 V
  • Double conversion on-line: sine-wave output with harmonic distortion below 3% and a 3:1 crest factor
  • Bypass: internal automatic and manual bypass
  • Input: 230 V single phase or 400 V three phase, 50/60 Hz ±5 Hz auto-sensing, input harmonic distortion below 7% at full load
  • Batteries: four internal lead-acid modules, typical recharge time 2 hours, battery life 3 to 5 years and runtime that can be extended
  • Management: pre-installed network management card with environmental monitoring, serial and USB ports and emergency power off

Key details

ModelSURT10000XLI
Output
Rated power8,000 W / 10,000 VA
Output voltage230 V single phase (configurable for 220 or 240 V)
Output frequency50/60 Hz ±3 Hz user adjustable ±0.1 Hz, synchronised to mains
Output voltage distortionLess than 3%
Crest factor3:1

See all technical details

Technical details

ModelSURT10000XLI
Output
Rated power8,000 W / 10,000 VA
Output voltage230 V single phase (configurable for 220 or 240 V)
Output frequency50/60 Hz ±3 Hz user adjustable ±0.1 Hz, synchronised to mains
Output voltage distortionLess than 3%
Crest factor3:1
TopologyOn-line (double conversion)
WaveformSine wave
Output connections4 × IEC 60320 C13, 4 × IEC 60320 C19, 6 IEC jumpers and hard wire 3-wire (H N + E) for 1 zone
BypassInternal bypass (automatic and manual)
Input
Input voltage230 V AC single phase or 400 V AC three phase (220 V and 240 V also supported)
Input voltage window160–280 V
Input frequency50/60 Hz ±5 Hz, auto-sensing
Input harmonic distortionLess than 7% at full load
Input connectionHard wire 3-wire (1P + N + E) or 5-wire (3P + N + E)
Batteries and runtime
Battery typeLead-acid, internal
Included battery modules4
Replacement batteryAPCRBC140 (2 cartridges)
Typical recharge time2 hours
Battery charging power955 W rated
Battery life3–5 years
Communications and management
Pre-installed deviceNetwork management card with environmental monitoring
ConnectivitySerial port, USB port
Emergency power offYes
AlarmsAlarm when on battery, distinctive low-battery alarm, continuous tone on overload
Noise filteringFull-time multi-pole, 0.3% IEEE surge let-through, zero clamping response time, meets UL 1449
Surge energy rating1,265 J
Physical
Height432 mm
Width263 mm
Depth736 mm
Net weight110.91 kg
FormatTower, 6U
ColourBlack
Environment
Operating temperature0–40 °C
Storage temperature−15 to 45 °C
Relative humidity0–95%, non-condensing
Acoustic level55 dBA
Heat dissipation2,262 Btu/h
Degree of protectionIP20
Operating altitude0–10,000 ft
Conformance
StandardsEN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2
CertificationCE, C-Tick, GOST, VDE
Warranty24 months

Product description

Double-conversion on-line protection

The APC Smart-UPS RT 10kVA online UPS provides double-conversion power protection at 8kW. Explore 10kVA online UPS features, scalable UPS runtime and internal battery backup.

The Smart-UPS RT 10kVA gives high-density, double-conversion on-line power protection with scalable runtime. The load is always supplied from the inverter with a sine-wave output, harmonic distortion below 3% and a 3:1 crest factor.

Input and bypass

The input is 230 V single phase or 400 V three phase at 50/60 Hz ±5 Hz with auto-sensing, and the input harmonic distortion is below 7% at full load. An internal bypass, automatic and manual, keeps the load supplied during service.

Batteries and runtime

Four internal lead-acid battery modules are fitted. The typical recharge time is 2 hours, the battery life is 3 to 5 years and the runtime can be extended. The replacement battery is APCRBC140.

Outputs

The output is 230 V single phase, configurable for 220 or 240 V. It offers IEC 60320 C13 and C19 outlets, IEC jumpers and a hard-wired connection.

Management and warranty

A network management card with environmental monitoring is pre-installed, with serial and USB ports and emergency power off. The UPS is delivered with software on CD, a service manual, a user manual and an RS-232 signalling cable, and carries a 24-month warranty.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.