About this item

  • Rating: 900 VA / 540 W, 230 V AC single-phase input and output, tower format
  • Line-interactive with AVR: 10 ms typical transfer time (12 ms maximum) and an input voltage window of 176–294 V
  • Outlets: six IEC 60320 C13 outlets, IEC 60320 C14 input and a USB port
  • Display: multifunction LCD status and control console, with a distinctive low-battery alarm and a continuous tone on overload
  • Battery: 12 V, 9.4 Ah lead-acid, user-replaceable (APCRBC164), typical recharge time 12 hours, battery life 3 to 5 years
  • Protection: full-time multi-pole noise filtering, 10% IEEE surge let-through and instantaneous zero clamping response

Key details

Model BR900MI
Output
Rated power 540 W / 900 VA
Output voltage 230 V AC, single phase
Output frequency 50/60 Hz ±1 Hz, synchronised to mains
Topology Line interactive
Waveform Stepped approximation to a sine wave

See all technical details

Technical details

Model BR900MI
Output
Rated power 540 W / 900 VA
Output voltage 230 V AC, single phase
Output frequency 50/60 Hz ±1 Hz, synchronised to mains
Topology Line interactive
Waveform Stepped approximation to a sine wave
Output connections 6 × IEC 60320 C13
Transfer time 10 ms typical, 12 ms maximum
Input
Input voltage 230 V AC, single phase
Input voltage window 176–294 V
Input frequency 50/60 Hz ±3 Hz, auto-sensing
Input connection IEC 60320 C14
Maximum input current 10 A
Batteries and runtime
Battery type Lead-acid, internal, user-replaceable
Battery voltage and capacity 12 V, 9.4 Ah
Replacement battery APCRBC164
Typical recharge time 12 hours
Battery life 3–5 years
Communications and management
Control panel Multifunction LCD status and control console
Alarms Alarm when on battery, distinctive low-battery alarm, continuous tone on overload
Connectivity USB port
Noise filtering Full-time multi-pole, 10% IEEE surge let-through, zero clamping response time
Physical
Height 190 mm
Width 91 mm
Depth 310 mm
Net weight 7.1 kg
Mounting Tower, not rack-mountable
Environment
Operating temperature 0–40 °C
Storage temperature −15 to 45 °C
Relative humidity 0–95%
Acoustic level 45 dBA
Operating altitude 0–10,000 ft
Heat dissipation 16.4 Btu/h
Conformance
Standards EN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2
Certification and marking CE, RCM, EAC, TISI, GS mark
Warranty 24 months

Product description

Line-interactive protection with AVR

The Back-UPS Pro BR900MI is a tower, line-interactive UPS rated 900 VA / 540 W. Automatic voltage regulation works within a 176–294 V input window, and the transfer time to battery is 10 ms typical (12 ms maximum). The output is a stepped approximation to a sine wave.

Outlets and connection

Six IEC 60320 C13 outlets supply the connected equipment. The UPS is fed through an IEC 60320 C14 input with a maximum input current of 10 A, and a USB port connects it to a computer.

Display and alarms

A multifunction LCD status and control console shows the state of the UPS. The alarms distinguish running on battery, a low battery and an overload, which has a continuous tone.

Battery

The internal 12 V, 9.4 Ah lead-acid battery is user-replaceable (replacement cartridge APCRBC164). The typical recharge time is 12 hours and the battery life is 3 to 5 years.

Protection and warranty

Full-time multi-pole noise filtering limits surges to 10% IEEE let-through with an instantaneous zero clamping response. The BR900MI is marked CE, RCM, EAC and TISI, carries the GS mark and is covered by a 24-month warranty.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.