Solis S6-EH1P 12–18kW single-phase hybrid inverter

Brand:

Solis S6-EH1P 12–18kW hybrid solar inverter with 3 MPPTs, 40–60V battery input and IP66 enclosure. View specifications.

Solis S6-EH1P 12–18kW single-phase hybrid inverter

Brand:

Solis S6-EH1P 12–18kW hybrid solar inverter with 3 MPPTs, 40–60V battery input and IP66 enclosure. View specifications.

About this item

  • Rating: single-phase hybrid inverter in 12, 14, 16 and 18 kW, 220 V / 230 V, 50 Hz / 60 Hz
  • PV side: 3 MPP trackers with 6 strings, 80–520 V MPPT range, 550 V maximum input voltage, PV input up to 160% of the rated DC power
  • Battery: Li-ion or lead-acid, 40–60 V, 250 to 320 A maximum charge and discharge current
  • Back-up: switchover in under 10 ms, twice the rated power for 10 s, generator input, up to 6 inverters in parallel
  • Efficiency: 97.6% maximum, 97.0% EU efficiency
  • Enclosure: IP66, intelligent redundant fan-cooling, −25 to +60 °C, 7.0-inch LCD, WiFi, LAN and Bluetooth with SolisCloud

Key details

ModelS6-EH1P(12-18)K03-NV-YD-L
Output AC (grid side)
Rated output power (12K / 14K / 16K / 18K)12 / 14 / 16 / 18 kW
Maximum apparent output power12 / 14 / 16 / 18 kVA
Rated grid voltageL/N/PE, 220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current (220 V / 230 V)54.5 A / 52.2 A (12K), 63.6 A / 60.9 A (14K), 72.7 A / 69.6 A (16K), 81.8 A / 78.2 A (18K)

See all technical details

Technical details

ModelS6-EH1P(12-18)K03-NV-YD-L
Output AC (grid side)
Rated output power (12K / 14K / 16K / 18K)12 / 14 / 16 / 18 kW
Maximum apparent output power12 / 14 / 16 / 18 kVA
Rated grid voltageL/N/PE, 220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current (220 V / 230 V)54.5 A / 52.2 A (12K), 63.6 A / 60.9 A (14K), 72.7 A / 69.6 A (16K), 81.8 A / 78.2 A (18K)
Power factor> 0.99 (0.8 leading to 0.8 lagging)
THDi< 3%
Input DC (PV side)
Recommended maximum PV array size24 / 28 / 32 / 36 kW
Maximum usable PV input power19.2 / 22.4 / 25.6 / 28.8 kW
Maximum input voltage550 V
Rated voltage380 V
Start-up voltage100 V
MPPT voltage range80–520 V
Maximum input current40 A / 40 A / 40 A (12K, 14K, 16K), 42 A / 42 A / 42 A (18K)
Maximum current per DC input20 A (12K, 14K, 16K), 21 A (18K)
Maximum short-circuit current50 A / 50 A / 50 A
MPPT number / maximum input strings3 / 6
Battery
Battery typeLi-ion / Lead-acid
Battery voltage range40–60 V
Maximum charge / discharge current250 A (12K), 290 A (14K), 290 A (16K), 320 A (18K)
Number of battery ports / BMS ports1 / 1
Battery communicationCAN / RS485
Output AC (back-up)
Rated output power12 / 14 / 16 / 18 kW
Maximum apparent output power2 times the rated power, 10 s
Back-up switch time< 10 ms (single inverter); < 20 ms (parallel system of up to 6 inverters)
Rated output voltageL/N/PE, 220 V / 230 V
Rated frequency50 Hz / 60 Hz
Rated output current (220 V / 230 V)54.5 A / 52.2 A (12K), 63.6 A / 60.9 A (14K), 72.7 A / 69.6 A (16K), 81.8 A / 78.2 A (18K)
Maximum AC passthrough current90 A
THDv (linear load)< 3%
Input AC (grid side)
Maximum input power18 / 21 / 24 / 27 kW
Input voltage range187–253 V
Maximum input current (220 V / 230 V)81.8 A / 78.3 A (12K), 95.5 A / 91.3 A (14K), 109.1 A / 104.3 A (16K), 122.7 A / 117.4 A (18K)
Input AC (generator side)
Maximum input power12 / 14 / 16 / 18 kW
Rated input current (220 V / 230 V)54.5 A / 52.2 A (12K), 63.6 A / 60.9 A (14K), 72.7 A / 69.6 A (16K), 81.8 A / 78.2 A (18K)
Rated input voltageL/N/PE, 220 V / 230 V
Rated input frequency50 Hz / 60 Hz
Efficiency
Maximum efficiency97.6%
EU efficiency97.0%
Battery charged by PV / AC, maximum efficiency> 94.9% / > 94.33%
Battery discharged efficiency93.51%
Protection
Surge protectionYes
Output overcurrent protectionYes
Insulation resistance monitoringYes
Residual current detectionYes
Integrated PV switchYes
DC reverse-polarity protectionYes (PV only)
Protection class / Overvoltage categoryI / II (PV and BAT), III (MAINS, BACKUP and GEN)
Integrated AFCI 2.0Optional
Anti-islanding protectionYes
General data
Dimensions (W × H × D)459 × 845 × 313 mm
Weight55.5 kg
Inverter topologyNon-isolated (PV), Isolated (Battery)
Self-consumption< 40 W
Operating temperature range−25 to +60 °C
Relative humidity0–100%
Ingress protectionIP66
Noise emission (typical)< 65 dB(A)
Cooling conceptIntelligent redundant fan-cooling
Maximum operation altitude4000 m
Grid connection standardNRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, EN50549-1
Safety / EMC standardIEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
PV connectionMC4 connector
Battery connectionTerminal block
AC connectionTerminal block
Display7.0" LCD display and Bluetooth + app
Communication interfaceStandard: WiFi + LAN + Bluetooth, CAN-BMS, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI, DO × 2; optional: 4G

Product description

A single-phase hybrid inverter from 12 to 18 kW

The Solis S6-EH1P 12–18kW is a single-phase hybrid solar inverter for solar-plus-battery systems. This Solis solar inverter combines three MPPT trackers, low-voltage battery compatibility and backup operation. Review its capacity options, input range and monitoring features for residential and commercial solar applications across Pakistan.

The Solis Solarator S6-EH1P(12-18)K03-NV-YD-L is a single-phase, low-voltage hybrid inverter in four ratings: 12, 14, 16 and 18 kW. It has three MPP trackers with six string inputs, a recommended PV array of 24, 28, 32 or 36 kW and a usable PV input power of 19.2, 22.4, 25.6 or 28.8 kW. The PV voltage range is 80–520 V with a 550 V maximum, and the maximum input current is 40 A per MPPT (42 A on the 18K).

Battery and back-up

The battery port takes Li-ion or lead-acid batteries between 40 and 60 V and communicates over CAN or RS485. The maximum charge and discharge current is 250, 290, 290 or 320 A, depending on the rating. When the grid fails, the back-up output supplies the rated power of the model and up to twice that for 10 seconds. The switchover from on-grid to off-grid takes less than 10 ms for one inverter, and less than 20 ms in a parallel system of up to 6 inverters. A generator can be connected to the AC input.

AC connections

The grid output is L/N/PE at 220 V or 230 V and 50 Hz or 60 Hz, with a power factor above 0.99 (0.8 leading to 0.8 lagging) and a current distortion (THDi) below 3%. The grid input accepts 187–253 V at up to 18, 21, 24 or 27 kW, the generator input takes 12, 14, 16 or 18 kW, and the maximum AC passthrough current is 90 A.

Efficiency and protection

The maximum efficiency is 97.6% and the EU efficiency 97.0%. Protection includes surge protection, output overcurrent protection, insulation resistance monitoring, residual current detection, an integrated PV switch, DC reverse-polarity protection (PV only) and anti-islanding protection. AFCI 2.0 is optional.

Installation and monitoring

The IP66 inverter weighs 55.5 kg and measures 459 × 845 × 313 mm (W × H × D). It is cooled by intelligent redundant fans, works from −25 to +60 °C at up to 4,000 m and has a typical noise below 65 dB(A). PV connection is by MC4 connectors; the battery and AC connections are terminal blocks. A 7.0-inch LCD display, WiFi, LAN and Bluetooth, and the SolisCloud platform give local and remote monitoring. The standard interfaces are CAN-BMS, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI and DO × 2; 4G is optional.

Source: manufacturer flyer and datasheet S6-EH1P(12-18)K-PH (file V2,1), Solis. Download it with the button above.

Price

On request

Pricing and availability are confirmed in your quotation. Tell us the quantity and where it is needed when you ask.

A black desk telephone beside an older dial telephone

Need help choosing?

Tell us the load, the backup time and the site. Our engineers will recommend the right rating and send an itemised quotation.

A black desk telephone beside an older dial telephone

Discuss your power requirements with our engineers

Tell us about the site, the load and the outcome you need. We will come back with a recommendation and a quotation, and an engineer can visit the site to check the roof or open space, the shading and the electrical connection before the design is fixed.